AWLR (Submersible Water Level) HPT605 (MTI.WL.SM.HK.605) a fully submersible level transducer suitable for vaste water or sewage level measurement. It consists of the U.S.A imported GE piezoresistive sensing element encased in 316 SS housing. It's all stainless steel, hermetically sealed housing make it sumable for immersion for a long time in most industrial sewage and vaste water.
Each submersible pressure transducer features a removable nose cone at the sensor which protects the diaphragm from damage. Units come equipped with a 270-pound tensile strength shielded and vented cable. Ventilation tube in the cable automatically compensates for changes in atmospheric pressure above the tank. The vent is protected with a maintenance free filter eliminating particulate or water droplets from entering the transducer.
HPT605 incorporates lightning and surge protection utilizing dual arrestor technology, to assure under the input and output short- circuit conditions to protect prevent reverse connection. Holykell can provide a cost effective solution for level monitoring for a variety of applications. Welcome your inquiry.
AWLR (Submersible Water Level) HPT605
• Range: 0~50m; 0~100m; 0~150m; 0-200m
• Parameter HPT605
• Pressure Range: 0-0.1 Bar.....20 Bar / 0-1m.....200m H2O Optional (See P1 page description) * 80m max for SDI-12 signal
• Overload: 150% F.S.
• Burst Pressure: 500% F.S.
• Accuracy: ≤ ±0.5%F.S (Typical) ; ≤ ±0.25%F.S(by customized) @25 degree C
• (Linearity Hysteresis Repeatability): Including non-lin., rep. and hys;Optional
• Long-term Stability: ≤ ±0.1%F.S. of span/year
• Working Temp. -40-80°C(non-corrosive medium)
• Storage Temp. -40°C~80°C(Nitrile rubber sealing ring); -20°C~80°C(fluororubber rubber sealing ring)
• Temperature Compensation: 0°C~80°C
• Medium compatible: Compatible with 316L Stainless Steel
• Electrical Wire: 2 Wires;3 Wires;4 wires
• Output: 4-20mA;1-5V;0-5V;0-10V;0.5-4.5V non-ratiometric;SDI-12;RS485 Modbus RTU
• Power Supply: 7-30Vdc;8-30Vdc;13-30Vdc;5Vdc±5%;12Vdc;3.5-36Vdc
• Polarity protection: Yes;Power wires-Yes; Signal Wires-Yes, Power&Signal Wires-No!
• Insulate resistance: >100M Ω@50V
• Zero Temp. Drift 0.2%FS/°C(≤100kPa); 0.1%FS/°C(>100kPa)
• FS Temp. Drift 0.02%FS/°C(≤100kPa); 0.01%FS/°C(>100kPa)
• Electrical connection: Fixed cable with vented tube and water proof IP68
• Response time: ≤10 ms
• Pressure Type: Gauge pressure; Sealed gauge and absolute optional
• Certificate TUV RoHS and CE Certificate
• EMC Standard EN 61326-1:2013; EN 61326-2-3:2013; EN 61000-6-2:2005; EN61000-6-4:2007+A1
• Lightning Protection (optional functions): Air conduction more than 8000V; external sensor more than 4000 Voltage protection.
• Cable optional: Cable materials are optional according request, we offer 3 type special cable as follow: PE Cable(Water Proof); PU Cable(Oil/Fuel Proof); FEP Cable(Anti-Corrosive)