top of page

WQMS For (Sparing) (MTI.WQMS.SPR.DRFN) Monitor your company's wastewater management and comply with the regulations of the Ministry of Environment and Forestry (KLHK). Allow us to assist you in implementing a Continuous and Networked Wastewater Quality Monitoring System (Sparing)

WQMS For (Sparing)

SKU: MTI.WQMS.SPR.DRFN
  • Chemical Oxygen Demand (COD) (COD UV351H)

    • Measuring Principle: UV254 Absorption Method

    • Optical path: 2mm

    • Measuring Range: COD: 1~1500mg/L;TOC: 0.4~600mg/L

    • Resolution: COD: 0.01mg/L TOC: 0.1mg/L

    • Accuracy: ± 3% of the measurement + 0.5mg/L

    • Related Measurement: TU: 0~300NTU accuracy: ± 5% TU: 0~1000NTU accuracy: ±5%Response Time >1min

    • Operating Tempe: 0~45℃ (does not freeze)

    • Storage Temp: -10~60℃

    • Calibration Method: Standard solution

    • Protection Grade: IP68

    • Working Pressure: ≤1bar

    • Flow Rate: not depend on

    • Power: DC 12V~24V

    • Communication: RS485, Modbus RTU protocol

    • Dimension: Diameter 60mm, length 215mm

    • Lead Interface: M16

    • Installation: Investment, 1 inch NPT pipe thread

    • Shell Material: POM and 316L

    • Power Consumption:

    - Normal measurement: 0.1W;

    - Automatic cleaning by mechanical wiper: 3W;

    - Abnormal jamming of mechanical wiper: 4.5W

    • Weight 720g

    pH (pH DPH 790)

    • Model: DPH790

    • Electrical Isolation: Luminescence optical measurement

    • Measuring Range: Dissolved oxygen: 0.00~20.00mg/L

    • Saturation: 0~200%

    • Temp: 0~50°C

    • Resolution: Dissolved oxygen: 0.01mg/L Saturation: 1% Temp: 0.1°C

    • Accuracy: Dissolved oxygen: ±0.3mg/L

    • Saturation: ±3%

    • Temp: 5~45°C

    • Response Time: T90<60s

    • Digital Output: RS485, Modbus RTU

    • Related Compensation: Temperature/salinity/pressure compensation

    • Calibration: Zero and span calibration

    • Sample Flow Rate: Not dependent

    • Work Pressure: 0~6Bar

    • Work Temp: 0~50°C

    • Storage Temp: -10~60°C

    • Material: Titanium alloy

    • Power Supply: DC 6~12V

    • Consumption: 0.1W

    • Dimensions: Diameter: 22mm Length: 160mm

    • Installation: Submersible; Thread specifications: M22*1.5mm

    • Lead Interface: M16

    • Protection Grade: IP68

    • Cable: Standard 5 meters (other length can be customized)

    • Weight: 100g

    • Application: Freshwater or seawater aquaculture

    Amoniak - nh4 Amonium NH351 (without K-compensation)

    • Model: NH351

    • Measuring Principle: Ion selective electrode (ISE) method

    • Measuring Range: NH4-N: 0~1000mg/L

    • Accuracy: NH4-N: 5% of the measured value ± 0.2mg/L pH: 0.1pH

    • Resolution: NH4-N: 0.01mg/L

    • Communication: RS-485, MODBU-RTU

    • Related Measurement: pH: 5.0~9.0pH (recommendation) K+: 0~1000mg/L (option)

    • Response Time: T90<2min

    • Temperature Range: 0~45℃ (does not freeze)

    • Storage Temperature: 0~50℃ (does not freeze)

    • Working Pressure: ≤1ba

    • Sample Flow Rate: 0.5m/s≥flow rate≥0.001m/s

    • Protection Grade: IP68

    • Calibration Method: Standard solution

    • Sensor Interface: Support

    • Lead Interface: M16

    • Shell Material: POM

    • Dimension: Diameter: 65mm Length: 275mm

    • Installation: Investment, 1 inch NPT pipe thread

    • Power Consumption: Normal measurement: 0.6W;

    • Weight: 620g

    Total Suspended Solid (TSS) (OPT850)

    • Model: OPTU850Z

    • Electrical Isolation: Electrical isolated communication and power interfaces

    • Measuring Technology Infrared scattering principle

    • Measuring Range: Turbidity: 0.01~1000NTU; Suspended solids: 1~3000mg/L (Only one parameter display can be selected at the same time)

    • Resolution: 0.01NTU/1mg/L

    • Accuracy: Better than 5% of measured value or 0.3NTU, take the larger one

    • Related Configuration: Humidity alarm

    • Response Time: T90<15s

    • Calibration Method: Multi-point calibration; Contrast Offset; Factor offset

    • Work Pressure: ≤4Bar

    • Sample Flow Rate: Not dependent

    • Operating Temp: 0~50℃ (does not freeze)

    • Storage Temp: -10~60℃ (does not freeze)

    • Shell Material: POM+SS 316L or POM+Titanium alloy

    • Dimension: Diameter: 52mm length: 260 mm

    • Mounting Thread: Horizontal installation, dedicated 90° mounting accessories

    • Lead interface: Split M16 connector

    • Protection Grade: IP68

    • Power Supply: 9~24V DC

    • Power Consumption: 0.6W

    • Weight: 700g

WhatsApp
bottom of page