GroPoint™(MTI.AWS,GP.MSSP) Profile provides cost-effective measurement of volumetric water content over multiple depths using a single probe, eliminating the cumbersome excavation required for multiple sensors placed at different depths. It can be deployed in irrigation-sensitive zones to enable full control of precision irrigation needs, providing an understanding of water movement through the soil.
The sleek, lightweight design installs quickly with minimal soil disruption using a pilot rod and slide hammer tool. Designed for vertical installation, the sensor takes measurements over multiple soil layers, with each measurement zone (segment) providing the average volumetric soil moisture content over a 15 cm range (approximately 6 inches).
Unlike any other soil profiling probe, GroPoint Profile provides true soil profiling quantification, measuring the average moisture across the entire length of each segment (15cm or 6″), because there are no gaps between segments. This unique feature allows measuring the water movement through the soil continuously, rather than just at discrete positions on the probe.
The Most Accurate and Cost-Effective Soil Profiling Solution Available
• Eliminates need for multiple sensors and cabling systems.
• Measures across the entire length of the probe, averaging the soil moisture and temperature in each segment
• Installs quickly and easily without excavating.
• One SDI-12 address is used to read all segments, providing for simplified installations. Optional RS-485 output.
• Moisture readings can be user-calibrated with 3rd-order polynomials to meet custom requirements.
• Low power requirements—suitable for remote, autonomous applications.
• Patented TDT5 technology for scientific-grade accuracy and excellent long-term stability of measurements.
• Fully potted electronics for excellent durability.
Multi-segment soil profiling sensor
Moisture
• Measuring Range: 8% to 40% VWC
• Repeability: <0.2%
• Accuracy: 2% to 5% for most soils, accuracy depends on soils
Temperature
• Measuring Range: -20°C to +70°C (-4°F to 158°F)
• Repeatability; -
• Accuracy: ±0.5°C
• Output: SDI-12V1.3 (RS485 optional)
• Input voltage: 6 t 14 VDC max. 18 VDC
• Current consumption: Quiescent: <0.5mA Active: 15-20 mA (depending on number of segments) for 100 mS
• Warm-up time on power up: -1 second
• Operating temperature: -20°C to 70°C (-4°F to 158°F)
• Storage temperature: -40°C to 85°C (-40°F to 185°F)
• Cable weight: 38 g per m (0.42 oz, per foot)
• Warrantly: 1-year limited ports and labor