WQMS For (Sparing) (MTI.WQMS.SPR.PBS) Monitor your company's wastewater management and comply with the regulations of the Ministry of Environment and Forestry (KLHK). Allow us to assist you in implementing a Continuous and Networked Wastewater Quality Monitoring System (Sparing)

WQMS For (Sparing)

SKU: MTI.WQMS.SPR.PBS
  • Spectroscopic COD | Include COD, BOD (PUVCOD-900)

    • Measuring Range

    1) COD (using KHP calibration):0~2000mg/l COD (2mm)

    2) 0~1000mg/l COD (5mm);0~90mg/l COD (50mm)

    3) BOD (using KHP calibration):0~1500mg/l BOD(2mm)

    4) 0~750mg/l BOD(5mm);0~60mg/l BOD(50mm)

    • Accuracy: ±5%

    • Measuring interval: Min one minute

    • Pressure Range: ≤0.4Mpa

    • Sensor material: SUS316L

    • Power Supply: AC:85-500VAC (50/60HZ) DC:9~36VDC

    • Output: 3-way 4-20mA

    • Relay: Setting three-way relays,programmed response parameter and response value.

    • Communication protocol: MODBUS RS485

    • Storage temperature: -15-65°C

    • Measuring temperature: 0-45°C

    • Dimensions: Sensor:Diam 69mm*Length 380mm Transmitter:145*125*162mm(L*W*H)

    • Weight: Sensor:3.2KG;Transmitter:1.35KG

    • Protective rate: Sensor:IP68/NEMA6P;Transmitter:IP65/ NEMA4X

    • Cable length: Standard:10m,the maximum may be extended to 100m

    Spectroscopic COD | Include COD, BOD (PUVCOD-600)

    • Measuring Range: COD (using KHP calibration):0~500mg/l COD ;BOD (using KHP calibration):0~375mg/L BOD;TOC(using KHP calibration):0~200mg/L TOCTurbidity:10-800 NTU

    • Accuracy: COD/BOD/TOC (using KHP calibration):±5%;Turbidity:±10%Repeatability 5% (using KHP calibration)

    • Resolution: COD/BOD/TOC:0.01 mg/l;Turbidity:0.01NTU

    • Pressure Range: ≤0.1Mpa

    • Sensor material: Body:SUS316L(fresh water),Titanium alloy(Ocean marine),Cable:PURPower Supply AC:85-500VAC (50/60HZ);DC:9-36VDC

    • Output: 3-way 4-20mA

    • Relay: Three-way relays, programmed response parameter and response value. Communication protocol MODBUS RS485

    • Storage temperature: -15-50℃

    • Measuring temperature: 0-45℃(Non-freezing)

    • Dimensions: Sensor:Diam 34mm*Length 217mm ;Transmitter:145*125*162mm(L*W*H)

    • Weight: Sensor:0.8KG;Transmitter:1.35KG

    • Protective rate: Sensor:IP68/NEMA6P;Transmitter:IP66/ NEMA4X

    • Cable length: Standard:10m,the maximum may be extended to 100m

    pH Sensor (MP301)

    • Principle: Glass electrode method

    • Range: 0-14 pH

    • Resolution: 0.01 pH

    • Accuracy: ±0.1 pH

    TSS Sensor (PSS-800)

    • Measurement Range: 0,01-20000 mg/L, 0,01-45000 MG/L, 0,01-120000 MG/L

    • Measurement accuracy: less than the ± 5% off measured value. (Depending on the homogeneity of sludge)

    • Pressure range: ≤ 0,4 Mpa

    • Flow Rate: ≤ 2.5 m/s, 8,2 ft /s

    • Calibration: Sample Calibraton, Slope calibration

    • Main material: Body SUS316L + PVC (Normal Version ) SUS316L titanizing + PVC (Sea Version): O- ring: fluoring rubber: cable: PVC

    • Powe supply: 100-240VAC (50/60HZ)

    • Output: 3- way 4-20mA

    • Relay: Setting three - way relays programmed response parameter and response value

    • Communication Protocol: MODBUS RS485

    • Storage Temperature: -15-65 °C

    • Operation Temperature: 0-45°C

    • Dimensions - Sensor: Dia 60 mm*Length256mm - Transmitter : 145*125*162mm(L*W*H)

    • Weight: Sensor 1.65kg: Transmitter: 1.35kg

    • Protective rate: Sensor IP68/NEMA6P: Transmitter:IP65/NEMA4X

    • Cable length: Standard 10m, the maximum may be extended to 100m

    Ammonia (MP301)

    • Principle: Ion selection

    • Range: 0.1~100mg/L-N

    • Resolution: 0.01mg/L-N

    • Accuracy: ±10% or ±2mg/L

    Debit (MP301)

    • Principle: Pressure-sensitive Method

    • Range: 0-61m(Maximum withstand pressure depth: 30M)

    • Resolution: 2cm

    • Accuracy: ±0.3%

WhatsApp