WQMS For (Sparing) (MTI.WQMS.SPR.PBS) Monitor your company's wastewater management and comply with the regulations of the Ministry of Environment and Forestry (KLHK). Allow us to assist you in implementing a Continuous and Networked Wastewater Quality Monitoring System (Sparing)
WQMS For (Sparing)
Spectroscopic COD | Include COD, BOD (PUVCOD-900)
• Measuring Range
1) COD (using KHP calibration):0~2000mg/l COD (2mm)
2) 0~1000mg/l COD (5mm);0~90mg/l COD (50mm)
3) BOD (using KHP calibration):0~1500mg/l BOD(2mm)
4) 0~750mg/l BOD(5mm);0~60mg/l BOD(50mm)
• Accuracy: ±5%
• Measuring interval: Min one minute
• Pressure Range: ≤0.4Mpa
• Sensor material: SUS316L
• Power Supply: AC:85-500VAC (50/60HZ) DC:9~36VDC
• Output: 3-way 4-20mA
• Relay: Setting three-way relays,programmed response parameter and response value.
• Communication protocol: MODBUS RS485
• Storage temperature: -15-65°C
• Measuring temperature: 0-45°C
• Dimensions: Sensor:Diam 69mm*Length 380mm Transmitter:145*125*162mm(L*W*H)
• Weight: Sensor:3.2KG;Transmitter:1.35KG
• Protective rate: Sensor:IP68/NEMA6P;Transmitter:IP65/ NEMA4X
• Cable length: Standard:10m,the maximum may be extended to 100m
Spectroscopic COD | Include COD, BOD (PUVCOD-600)
• Measuring Range: COD (using KHP calibration):0~500mg/l COD ;BOD (using KHP calibration):0~375mg/L BOD;TOC(using KHP calibration):0~200mg/L TOCTurbidity:10-800 NTU
• Accuracy: COD/BOD/TOC (using KHP calibration):±5%;Turbidity:±10%Repeatability 5% (using KHP calibration)
• Resolution: COD/BOD/TOC:0.01 mg/l;Turbidity:0.01NTU
• Pressure Range: ≤0.1Mpa
• Sensor material: Body:SUS316L(fresh water),Titanium alloy(Ocean marine),Cable:PURPower Supply AC:85-500VAC (50/60HZ);DC:9-36VDC
• Output: 3-way 4-20mA
• Relay: Three-way relays, programmed response parameter and response value. Communication protocol MODBUS RS485
• Storage temperature: -15-50℃
• Measuring temperature: 0-45℃(Non-freezing)
• Dimensions: Sensor:Diam 34mm*Length 217mm ;Transmitter:145*125*162mm(L*W*H)
• Weight: Sensor:0.8KG;Transmitter:1.35KG
• Protective rate: Sensor:IP68/NEMA6P;Transmitter:IP66/ NEMA4X
• Cable length: Standard:10m,the maximum may be extended to 100m
pH Sensor (MP301)
• Principle: Glass electrode method
• Range: 0-14 pH
• Resolution: 0.01 pH
• Accuracy: ±0.1 pH
TSS Sensor (PSS-800)
• Measurement Range: 0,01-20000 mg/L, 0,01-45000 MG/L, 0,01-120000 MG/L
• Measurement accuracy: less than the ± 5% off measured value. (Depending on the homogeneity of sludge)
• Pressure range: ≤ 0,4 Mpa
• Flow Rate: ≤ 2.5 m/s, 8,2 ft /s
• Calibration: Sample Calibraton, Slope calibration
• Main material: Body SUS316L + PVC (Normal Version ) SUS316L titanizing + PVC (Sea Version): O- ring: fluoring rubber: cable: PVC
• Powe supply: 100-240VAC (50/60HZ)
• Output: 3- way 4-20mA
• Relay: Setting three - way relays programmed response parameter and response value
• Communication Protocol: MODBUS RS485
• Storage Temperature: -15-65 °C
• Operation Temperature: 0-45°C
• Dimensions - Sensor: Dia 60 mm*Length256mm - Transmitter : 145*125*162mm(L*W*H)
• Weight: Sensor 1.65kg: Transmitter: 1.35kg
• Protective rate: Sensor IP68/NEMA6P: Transmitter:IP65/NEMA4X
• Cable length: Standard 10m, the maximum may be extended to 100m
Ammonia (MP301)
• Principle: Ion selection
• Range: 0.1~100mg/L-N
• Resolution: 0.01mg/L-N
• Accuracy: ±10% or ±2mg/L
Debit (MP301)
• Principle: Pressure-sensitive Method
• Range: 0-61m(Maximum withstand pressure depth: 30M)
• Resolution: 2cm
• Accuracy: ±0.3%